Item |
Test Method |
Specification |
Insulation Resistance |
DC 500V |
More than100MΩ.m |
Dielectric strength between conductors |
AC 500V,duration 1minute |
No material breakdown |
Conduction Test |
DC3.0V 0.1mA |
No open and Short Circuit |
Conductor Resistance Test |
Normal temperature and humidity |
≤2260mΩ/M |
Coating thickness Test |
Indoor environment,test duration for 30seconds. |
Ni≧20u” Au≧3u” |
Match Test |
Continue to mate and unmate with the connectors for 30 cycles. |
Conductor not peeling |
180 degree folding test |
Folding Morther 20times |
No broken with insulation and no open circuit |
Abrasion Test |
0.5R 600g, 60 times/Min,More than 10,000 Times |
No broken with insulation and no open circuit |
Flexibility Test |
R:10mm,Speed:160cycles/min.Displacement:30mm,More than 100,000 Times |
No broken with insulation and no open circuit |
Heat Resistance Test |
105℃ for 96hours |
Insulation resistance≥100MΩ.m Dielectric strength test with AC500V/1min no brokendown |
Cold Resistance Test |
-40℃ for 96hours |
Insulation resistance≥100MΩ.m Dielectric strength test with AC500V/1min no brokendown |
Humidity Resistance Test |
40℃,95﹪RH,96H |
Insulation resistance≥100MΩ.m Dielectric strength test with AC500V/1min no brokendown |
Temperature Cycle Test |
[-40℃*(4H)→25℃*(1H)→105℃*(4H)→25℃*(1H)] × 5 cycles |
Insulation resistance≥100MΩ.m Dielectric strength test with AC500V/1min no brokendown |
Salt Water Spray Test |
Temperature:35℃ Salt concentration:5% Duration:48H Salt PH value:6.5-7.2 Sample located angle:15º-30º |
No bare conductor |
Adhesive force of Conductor |
Normal temperature and humidity |
(WIQA08) |
Adhesive force of supporting tape |
Normal temperature and humidity |
(WIQA08) |